Changes in the Pacemaker Rate After Transition From Edwards SAPIEN XT to SAPIEN 3 Transcatheter Aortic Valve Implantation: The Critical Role of Valve Implantation Height.

De Torres-Alba F, Kaleschke G, Diller GP, Vormbrock J, Orwat S, Radke R, Reinke F, Fischer D, Reinecke H, Baumgartner H

Research article (journal) | Peer reviewed

Abstract

OBJECTIVES: The aim of this study was to analyze the pacemaker implantation rate (PMIR) with the new balloon-expandable Edwards SAPIEN 3 valve (S3) and the factors associated with it. BACKGROUND: The introduction of the S3 for transcatheter aortic valve replacement (TAVR) has led to a reduction in paravalvular regurgitation. There are, however, concerns that the new design may increase the PMIR. METHODS: The first 206 patients treated with the S3 were compared with 371 preceding patients treated with SAPIEN XT valves. Patients who previously underwent pacemaker or implantable cardioverter defibrillator implantation or transapical and valve-in-valve procedures were excluded from the analysis. All patients were monitored for at least 7 days. Previous and new conduction abnormalities were documented, and prosthesis implantation height was assessed for the S3. RESULTS: There were no significant differences in baseline characteristics between groups. The PMIR was, however, significantly higher for the S3 (19.1% vs. 12.2%; p = 0.046). The mean implantation height was significantly lower in patients requiring PMI (67%/33% vs. 72%/28% aortic/ventricular stent extension, p = 0.032). On multivariate regression analysis, implantation height was the only independent predictor of PMI (odds ratio: 0.94 [95% confidence interval: 0.90 to 0.99]; p = 0.009). It increased from 68%/32% to 75%/25% when comparing the first with the second half of S3 implantations (p < 0.0001). This change was associated with a significant decrease in PMIR from 25.9% to 12.3% (p = 0.028), no longer different from the XT valve (12.2%). C ONCLUSIONS: The PMIR after TAVR is higher with the S3 than with the XT and is independently associated with the implantation height. This increase in the PMIR may be avoided by intending an aortic stent extension >70%.

Details about the publication

Volume9
Issue8
Page range805-813
StatusPublished
Release year2016
Language in which the publication is writtenEnglish
DOI10.1016/j.jcin.2015.12.023
KeywordsEdwards SAPIEN 3; balloon-expandable valve; conduction abnormalities; pacemaker; transcatheter aortic valve replacement

Authors from the University of Münster

Baumgartner, Helmut
Department for Cardiovascular Medicine
Diller, Gerhard-Paul
Department for Cardiovascular Medicine
Fischer, Dieter
Department for Cardiovascular Medicine
Kaleschke, Gerrit Tobias
Department for Cardiovascular Medicine
Orwat, Stefan
Department for Cardiovascular Medicine
Radke, Robert
Department for Cardiovascular Medicine
Reinecke, Holger
Klinik für Kardiologie I
Reinke, Florian
Department for Cardiovascular Medicine
Torres Alba, Fernando
Department for Cardiovascular Medicine
Vormbrock, Julia
Department for Cardiovascular Medicine