A Comparative Analysis of Carlevale IOL Versus Artisan IOL Implantation Using a Scleral Tunnel Incision Technique.

Obergassel J; Heiduschka P; Alten F; Eter N; Clemens CR

Research article (journal) | Peer reviewed

Abstract

Background: The aim of this retrospective study was to compare the surgical and refractive outcomes using the Carlevale IOL (FIL SSF; SOLEKO) with those of the retropupillary-fixated Artisan IOL (Aphakia Model 205; OPHTEC), implanted through a 6 mm sclerocorneal tunnel incision in both groups. Methods: This study included 51 consecutive eyes (25 Carlevale and 26 Artisan IOLs). Due to complex preoperative conditions (e.g., dislocated polymethylmethacrylat IOL, luxated Cataracta rubra), all patients underwent lens explantation using a standardized 6 mm sclerocorneal tunnel incision and a 23 G or 25 G pars plana vitrectomy. Visual acuity (VA), spherical equivalent, refractive prediction error (PE), incision-suture time, and complication rates were recorded preoperatively and during the follow-up period. Results: The average follow-up period was 40.9 ± 5.7 days. VA improved by 0.28 ± 0.39 logMAR (p < 0.0001) in the Carlevale group and by 0.36 ± 0.47 logMAR (p < 0.0001) in the Artisan group. The improvement was comparable between both groups (p = 0.921). The deviation of the PE was -0.67 ± 0.56 in the Carlevale group and 0.34 ± 0.71 in the Artisan group (p < 0.0001). The mean incision-suture time was 42.5 ± 5.8 min in the Carlevale group and 28.2 ± 6.4 min in the Artisan group. Anterior chamber and vitreous hemorrhages were the most common complications, occurring in 12% in the Carlevale group and 17.2% in the Artisan group. Conclusions: The use of the Carlevale IOL, implanted using a sclerocorneal tunnel technique, presents a valid option for treating complex lens dislocations. The scleral fixation of the Carlevale IOL minimizes risks associated with iris fixation, such as chronic inflammation and pupil distortion, making it particularly suitable for patients with damaged irises.

Details about the publication

JournalJournal of Clinical Medicine (JCM)
Volume13
Issue22
StatusPublished
Release year2024 (19/11/2024)
Language in which the publication is writtenEnglish
DOI10.3390/jcm13226964
KeywordsCarlevale intraocular lens; artisan intraocular lens; intraocular lens luxation

Authors from the University of Münster

Alten, Florian
Clinic for Ophthalmology
Clemens, Christoph
Clinic for Ophthalmology
Eter, Nicole
Clinic for Ophthalmology
Heiduschka, Peter
Clinic for Ophthalmology
Obergassel, Justus
Clinic for Ophthalmology