Hydroxyethyl starch (HES) solutions are frequently used for perioperative volume replacement. Whereas older HES specimen tended to accumulate in the plasma and to cause negative effects on hemostasis, more recent products, e.g., HES 130/0.4, are characterised by improved pharmacological properties. The present study was designed to compare the efficacy and safety of 10% HES 130/0.4 and 10% HES 200/0.5.In this post-hoc analysis of a prospective, randomised, double-blind, multi-center therapeutic equivalence trial, 76 patients undergoing elective on-pump cardiac surgery received perioperative volume replacement using either 10% HES 130/0.4 (N.=37) or 10% HES 200/0.5 (N.=39) up to a maximum dose of 20 mL kg-1.Equivalent volumes of investigational medication were infused until 24 hours after the first administration (1577 vs. 1540 mL; treatment difference 37 [-150; 223] mL; P<0.0001 for equivalence). Whereas standard laboratory tests of coagulation were comparable between groups, von Willebrand factor activity on the first postoperative morning tended to be higher following treatment with 10% HES 130/0.4 as compared to 10% HES 200/0.5 (P=0.025) with this difference being statistically significant only in the per-protocol analysis (P=0.02). Treatment groups were comparable concerning other safety parameters and the incidence of adverse drug reactions. In particular, renal function was well preserved in both groups.Ten percent HES 130/0.4 was equally effective and safe as compared to 10% HES 200/0.5 for volume therapy in patients undergoing cardiovascular surgery. Postoperative coagulation and renal function, as measured by standard laboratory tests, were similar among groups.

Details zur Publikation

FachzeitschriftMinerva Medica
Jahrgang / Bandnr. / Volume103
Ausgabe / Heftnr. / Issue2
Seitenbereich111-122
StatusVeröffentlicht
Veröffentlichungsjahr2012
Sprache, in der die Publikation verfasst istEnglisch
StichwörterGermany; Middle Aged; Double-Blind Method; Heart Valves; Humans; Plasma Substitutes; Cardiopulmonary Bypass; von Willebrand Factor; Hetastarch; Blood Coagulation Tests; Factor VIII. Prospective Studies; Male; Female; Germany; Middle Aged; Double-Blind Method; Heart Valves; Humans; Plasma Substitutes; Cardiopulmonary Bypass; von Willebrand Factor; Hetastarch; Blood Coagulation Tests; Factor VIII. Prospective Studies; Male; Female

Autor*innen der Universität Münster

Ertmer, Christian
Klinik für Anästhesiologie, operative Intensivmedizin und Schmerztherapie
Van Aken, Hugo K.
Klinik für Anästhesiologie, operative Intensivmedizin und Schmerztherapie
Westphal, Martin
Klinik für Anästhesiologie, operative Intensivmedizin und Schmerztherapie